DC Contactor ZLJM-400F Product Specifications
- Material used: AgCdO series (12)
- Contact rating (resistive load): 400A 48VDC/400A 250VAC
- Maximum switching voltage: 48VDC, 250VAC
- Maximum switching power supply: 100KVA
- Overload current duration (7Ie / 10S): 2800A / 10S
- Coil rated voltage: 12V, 24V, 30V, 48V, 60V, 120V
- Contact pressure drop: up to 30mV at 100A
- Insulation resistance: 100MΩ at min.500VDC
- Dielectric strength (between insulated electrical parts): 1000VAC 50 HZ / 60 HZ (1 minute)
- Operating time: up to 50 milliseconds.
- Ambient temperature: -40 ° C ~ + 85 ° C
- Mechanical life: 100,000 operations
DC Contactor ZLJ-400A Product Specifications
- Contact Material: AgCdO Series (12)
- Contact rating (resistive load): 400A 48VDC/400A 250VAC
- Maximum switching voltage: 48VDC, 250VAC
- Maximum switching power supply: 100KVA
- Overload current duration (7Ie / 10S): 2800A / 10S
- Coil rated voltage: (12, 24, 48, 60, 72, 120) VDC, etc.
- Contact pressure drop: up to 30mv at 100A
- Insulation resistance: 100MΩ at min.500VDC
- Dielectric strength (between insulated electrical parts): 1000VAC 50 HZ / 60 HZ (1 minute)
- Operating time: up to 50 milliseconds.
- Ambient temperature: -25 ° C ~ + 60 ° C
- Mechanical life: 100,000 operations
Characteristics
1.400A contact switch function
2.SPST-NO contact arrangement
3. Coil power waste: 8.5W
4. Uses: Suitable for electrical control systems such as communication power supplies, construction machinery, electric forklifts, automobiles, trains, ships, UPS, etc.