■ FEATURES
·500A rating current (Continues current), 200A breaking current,small volume;
·Switch DC loads at both low and high voltage from 12 to 900VDC;
·Coil power is very low, built-in coil economizer only1.7W;
·Application:For Electric Control System,Communication Power Supply,The solar system,Heavy truck,Emergency vehicles,Boats,Light rail,Mining,The charging system,Train,UPS etc. ;
·Safety Approvals: UL、CCC
DH150-250 High Voltage DC Contactor DH200H
■ SPECIFICATION
Product No. | DH200A |
Contact type | SPST-NO |
Contact current(continues current) | 500A |
Breaking current | 200A |
Contact rated operating voltage | 12~900V |
The maximum switch current | 2000A(320VDC) 1 Operations |
Contact voltage drop | Max. 80mV at 100A |
Pick-up Voltage(V) | (40~70)% of Coil Rated Voltage |
Drop-out Voltage(V) | (5~40)% of Coil Rated Voltage |
Close(Includes bouncing time)Max | Max. 20ms. |
Contact bouncing on close | Max. 7ms. |
Release Time | Max. 12ms. |
Vibration, Sinusoidal(10~2000Hz peak) | ≤20g |
Shock(11ms,1/2sine、peak、operating) | ≤20g |
Operating ambient temp range | -40℃~+85℃ |
Storage ambient temp range | -55℃~+120℃ |
Insulation Resistance | Min. 100MΩ @ 500VDC |
Dielectric Strength (Between Insulated Electric Parts) |
2200VAC 50 Hz/60 Hz (1 minute) |
Electrical Life | Table 1 |
Mechanical Life | 300000 Operations |
AUX. Type | 1NO |
AUX. Contact load range | 2A/30V DC / 3A 125VAC |
Aux. Contact Min. load | 100mA/8V |
Mounted direction | any direction |
Weight | 0.55kg |
■PRODUCT MODEL DEFINE:
■RESISTIVE LOAD UNDER DIFFERENT VOLTAGES
Table 1 Current carry VS Time
NOTE:
1、Electrical Life based on resistive loads,for resistive loads with 300uH maximum inductance;
2、The maximum make current is 650A to avoid contact welding;
3、End of life is defined as when the dielectric, insulation resistance or contact resistance exceeds
the specification listed;
▇ DIMENSION AND CIRCUIT DIAGRAM