■ FEATURES
·125A Contact Switching Capability
·2H (DPST-NO) Contact Arrangement
·Max Coil Power Dissipation :12W
·Application:For Electric Control System Of Communication Power Supply、Engineering Machine、Electromotion Forklift、Motor Car、Train、Watercraft and UPS etc.
SBDT & DPDT DC Contactor ZLJM-125D 2H
Model No. |
ZLJM—125D 1Z |
Contact Arrangement |
2H (DPST-NO) |
Contact Material |
AgCdO(12) |
Contact Rating(at Resistive Load) |
125A 80VDC 125A 250VAC |
Max. Switching Voltage |
80VDC,250VAC |
Max. Switching Power |
25000VA(AC);10000VA(DC) |
Endurance of Over Loading Current(7Ie/10S) |
875A/10S |
Coil Rated Voltage |
(12、24、48、60、72、120)VDC, etc. |
Pick-up Voltage |
(40~70)% of coil rated voltage |
Drop-out Voltage |
(5~30)% of coil rated voltage |
Contact Pressure Drop |
At most 80mv when 100A |
Insulation Resistance |
Min. 100MΩ at 500VDC |
Dielectric Strength (Between Insulated Electric Parts) |
1000VAC 50 HZ/60 HZ (1 minute) |
Operate Time |
Max. 50mSec. |
Release Time |
Max. 50mSec. |
Ambient Temperature |
-25℃~+60℃ |
The shocking of fixed point |
(10~200)HZ、acceleration≤3.5g |
Shocking |
(60~100) time/minute、acceleration≤4g |
Mechanical Life |
100,000 Operations (no load) |
Electrical Life |
10,000 Operations (at rated load) |
GET A QUOTE